Title: A Comparative Study of Various Screening Algorithms in the Diagnosis of Syphilis

Authors: Thilakavathi Natesan, V. Sudha

 DOI: https://dx.doi.org/10.18535/jmscr/v7i5.86

Abstract

Introduction: Worldwide two strategies are followed to diagnose syphilis. One is conventional method of testing the serum by non-specific treponemal test VDRL followed by specific Treponemal Pallidum Hemagglutination Assay (TPHA). The other method is viceversa. We aim to study the percentage of syphilis case detection rate by both the methods.

Material and Methods: A retrospective cross-sectional study was conducted amongst the high risk group patients attending the STD-OP of Institute of Venereology, Chennai for a period of 12 months. The study population was divided into 2 groups. Group A with conventional screening method (i.e. VDRL followed by TPHA) and Group B with TPHA followed by VDRL.

Results: A total of 1527 cases were recruited into the study, 767 in Group A and 760 in Group B. Group A: Out of 767 cases, 90 (11.7%) were reactive by VDRL. 65 (72.2%) were TPHA positive among the 90 VDRL reactive. The case detection rate and correlation between the two tests were 11.7% and 72.2% respectively. Group B: Out of 760 cases, 263 (34.6%) were TPHA positive 166 were VDRL reactive among the TPHA positive. The case detection rate and correlation between the two tests were 34.6% and 63.1% respectively.

Conclusion: The results of comparative data clearly demonstrate that the case detection rate was higher (three times) in reverse screening than that of conventional screening method. In conclusion, consistent with recommendations, laboratories should consider implementing the reverse algorithm for the diagnosis of syphiilis.

References

  1. Global prevalence and Incidence of selected curable sexually transmitted infections Overview and estimates and estimates WHO/HIV_AIDS/2001.02 WHO/CDS/CSR/EDC/2001.10.
  2. Lipinsky Dafna, Schreiber Licita, Kopel Vered, Shainberg Bracha. Validation of reverse sequence screening for syphilis.J Clin Microbiol. 2012 April;50:1501. http://dx.doi.org/10.1128/JCM.06286-11.
  3. Huh HJ, Lee KK, Kim ES, Chae SL. Analysis of positive resultsin mediace rapid plasma reagin and Treponema pallidum latex agglutination as the automated syphilis test. Korean J LabMed. 2007 Oct;27:324e329.
  4. Binnicker MJ, Jespersen DJ, Rollins LO. Direct comparison ofthe traditional and reverse syphilis screening algorithms in a population with a low prevalence of syphilis. J Clin Microbiol. 2012;50:148e150.
  5. Loeffelholz MJ. It is time to use treponema-specific antibody screening tests for diagnosis of syphilis. J Clin Microbiol. January 2012;50:2e6.
  6. Marangoni A, Moroni A, Accardo S, Cevenini R. Laboratory diagnosis of syphilis with automated immunoassays. J ClinLab Anal. 2009;23:1e6.
  7. Marangoni A, Sambri V, Accardo S, et al. Evaluation of LIAISON Treponema Screen, a novel recombinant antigen based chemiluminescence immunoassay for laboratory diagnosis of syphilis. Clin Diagn Lab Immunol.2005;12:1231e1234.
  8. Health Protection Agency. Serological Diagnosis of Syphilis, National Standard Method, London, United Kingdom.vol. 44. 2007.Available from: http://www.hpa-tandardmethods.org.uk.
  9. Gratrix J, Plitt S, Lee BE, et al. Impact of reverse sequence syphilis screening on new diagnoses of late latent syphilis in Edmonton, Canada. Sex Transm Dis. 2012;39:528e530.
  10. Geusau A, Kittler H, Hein U, Dangl-Erlach E, Stingl G, Tschachler E. Biological false-positive tests comprise a high proportion of Venereal Disease Research Laboratory reactionsin an analysis of 300,000 sera. Int J STD AIDS. 2005Nov;16:722e726.

Corresponding Author

Thilakavathi Natesan

Associate Professor, Department of Serology, Madras Medical College, India